Aging cheese needs 50-58°F (10-14°C) and 80-90% humidity, plus gentle air movement and darkness. Humidity can be measured with two thermometers, one wrapped in a wet wick, but at 12°C the wet bulb reads only 0.9 to 1.8°C below the dry bulb across the whole 90% to 80% band, so a thermometer that cannot be read to a tenth of a degree cannot tell a good cave from a bad one.

The aging conditions are the temperature and relative humidity at which a pressed cheese ripens without drying out, sweating fat or growing the wrong mold.

The Band Is Narrow, And Each Edge Has A Different Failure

The parent article specifies 50-58°F (10-14°C) and 80-90% humidity. Cheese Basics gives 10-15°C and the same humidity band, so the ranges agree where they overlap.

ConditionToo lowToo high
TemperatureRipening is slowCheese ripens fast and may sweat fat
HumidityRind cracks and cheese loses weightSlime and unwanted mold
Air movementMold builds up (dead air)Cheese dries

Hold temperature steady rather than perfect: a cave that swings widely within the band is worse than one that sits at 54°F all year.

What You Need

  • Two thermometers of the same make, one wrapped in a clean wick of cloth
  • Clean water for the wick and a way to move air over it, such as swinging the pair on a cord for a minute
  • A pan of water and a damp cloth to raise humidity; a gentle draft to lower it

Method: Measuring Humidity With A Wet Bulb

Wrap the bulb of one thermometer in a wick wetted with clean water and fan it. Evaporation cools it to the wet-bulb temperature; the difference from the dry bulb tells you the humidity. The drier the air, the bigger the difference.

Worked Example: What 80-90% Looks Like On Two Thermometers

At a dry-bulb of 12°C (53.6°F) the difference between dry and wet bulb for each humidity is:

Relative humidityWet-bulb depression at 12°C
90%about 0.9°C
85%about 1.3°C
80%about 1.8°C

These were computed from the Magnus vapor-pressure formula and the standard psychrometer constant of 0.00066 per degree at sea-level pressure, both from general knowledge and not from this wiki, so treat them as approximate. The working for 85%:

  • Saturation vapor pressure at 12°C is about 14.0 hPa, so the air holds 0.85 × 14.0 = 11.9 hPa.
  • A wet bulb at 10.7°C has saturation pressure about 12.8 hPa, and subtracting the psychrometer term 0.00066 × 1,013 hPa × 1.3°C ≈ 0.87 hPa gives 11.9 hPa. It matches, so the depression is 1.3°C.

The practical lesson is that the whole 80-90% band spans less than 1°C of wet-bulb difference. A thermometer marked in whole degrees, or read by eye to half a degree, cannot place a cave inside the band. Use one with 0.1-0.2°C resolution, check both against each other in the same air first so any offset between them is known, and measure at several spots.

Method: Adjusting The Cave

Too dry (high depression): set a pan of water on the floor, hang damp cloths, or reduce ventilation. The parent article names the water pan.

Too damp (low depression, slime on rinds): increase ventilation, and wipe mold with a cloth dipped in salted water or vinegar as Cheese Basics advises.

Too warm: this is a site or depth problem and cannot be fixed with a pan; see Natural cave vs built cellar.

Common Mistakes

  • Putting the wet-bulb thermometer in still air. It will read too high and the cave will look wetter than it is.
  • Using one thermometer for both readings in turn. The wick cooling it makes the second reading wrong.
  • Chasing a perfect number. Stability matters more than any one reading.
  • Opening the door in summer to cool a cave. Warm outside air cools on the cheese and condenses on it.

Safety

Wet floors and closed rooms

A damp cave floor is slippery and low spaces can hold carbon dioxide; ventilate before entering a space that has been closed for days and do not enter alone.

What’s Next